Echoson

PIROP A+B+CCT

Biometry, ultrasound and pachymetry in one ophthalmic scanner.

Ophthalmic ultrasound instrument for biometry. Ocular imaging and pachymetry. A-scan + B-scan + CCT pachymeter.

PIROP A+B+CCT · Equipment view

Key advantages

The documented strengths of PIROP A+B+CCT, at a glance.

A-mode biometry

Axial length and intraocular lens power calculation.

B-mode ultrasound

Ultrasound imaging of structures within the eyeball.

CCT pachymetry

Ultrasound measurement of corneal thickness.

Capabilities in practice

A closer look at the functions and technology of PIROP A+B+CCT.

Designed for a smoother workflow

Contact or immersion biometry

A mode measures axial length, anterior chamber depth, lens thickness and vitreous length. The A probe operates at 12 MHz.

PIROP A+B+CCT · Manufacturer report
PIROP A+B+CCT · Manufacturer report

Manufacturer illustration: the configuration shown may differ from the delivered configuration.

Several B-mode views

Ultrasound offers B, B+A and B+B views, separate memories for each eye and an approximately 6-second cine loop.

PIROP A+B+CCT · Manufacturer capture
PIROP A+B+CCT · Manufacturer capture

Manufacturer illustration: the configuration shown may differ from the delivered configuration.

Designed for daily practice

Explore the documented features and practical configuration of PIROP A+B+CCT.

Pachymetry and maps

The pachymetry probe operates at 20 MHz. The published range is 220–1100 µm, with nine predefined maps and measurement averaging.

PIROP A+B+CCT · Manufacturer report
PIROP A+B+CCT · Manufacturer report

Manufacturer illustration: the configuration shown may differ from the delivered configuration.

Storage and reports

The scanner provides an internal patient database and USB storage. Its internal thermal printer produces A-scan and P-scan reports.

Clearly identified software extensions

PIROP-PC manages examinations on a Windows computer. DICOM 3.0 support for PACS/RIS is an additional option.

PIROP-PC and DICOM are optional; installation is not assumed.

Technical information

Technical specifications & documentation

Product information, specifications and available documentation in one place.

Product specifications overview

Key documented information for this exact model.

Brand
Echoson
Model
PIROP A+B+CCT
Technology
Ophthalmic ultrasound
Clinical use
Imaging and OCT · Diagnostics and biometry
Modules
A-Scan + B-Scan + CCT

Probe frequency; internal algorithm frequency excluded.

Axial clinical resolution in B mode.

Options are not assumed included.

With printer.

Downloads & resources

Available product sheets and public manufacturer resources.

No public manufacturer document has been verified for this model. Contact ASEM for the available documentation.

Sources and documentation

Frequently asked questions

Your questions about PIROP A+B+CCT

Clear answers based on the available product information.

What is the documented Minimum pachymetry of PIROP A+B+CCT?
What is the documented Maximum pachymetry of PIROP A+B+CCT?

1100 µm

View source
Which configuration should I confirm for PIROP A+B+CCT?

Probe frequency; internal algorithm frequency excluded.

View source
Does the pachymetry probe operate at 400 MHz?

No. The probe is specified at 20 MHz. The manufacturer’s 400 MHz figure concerns internal sampling, not transducer frequency.

View source
Is DICOM included in every device?

The manufacturer lists PIROP-PC as an optional accessory and DICOM 3.0 as an additional option. Availability must be checked in the ordered configuration.

View source

ASEM support

More than a device, a long-term partnership

Discuss your project with ASEM: equipment selection, installation, training and technical support.

Installation

Discuss the installation requirements and configuration with our technical team.

Learn more
Service illustration
Service illustration

Training

Ask about the training and familiarisation available for your equipment.

Learn more
Service illustration
Service illustration

After-sales service

Contact ASEM for technical assistance and the support appropriate to your equipment.

Learn more
Service illustration
Service illustration

Expert advice

Tell us about your clinical needs to discuss a suitable equipment selection.

Learn more
Service illustration
Service illustration

Clinical applications

Explore the ASEM clinical catalogue

Browse related areas of the ASEM catalogue. These links do not extend the indications of this device.

Explore all products