Biometry, ultrasound and pachymetry in one ophthalmic scanner.
Ophthalmic ultrasound instrument for biometry. Ocular imaging and pachymetry. A-scan + B-scan + CCT pachymeter.
Key advantages
The documented strengths of PIROP A+B+CCT, at a glance.
A-mode biometry
Axial length and intraocular lens power calculation.
B-mode ultrasound
Ultrasound imaging of structures within the eyeball.
CCT pachymetry
Ultrasound measurement of corneal thickness.
Capabilities in practice
A closer look at the functions and technology of PIROP A+B+CCT.
Manufacturer illustration: the configuration shown may differ from the delivered configuration.
Manufacturer illustration: the configuration shown may differ from the delivered configuration.
Manufacturer illustration: the configuration shown may differ from the delivered configuration.
Designed for a smoother workflow
Contact or immersion biometry
A mode measures axial length, anterior chamber depth, lens thickness and vitreous length. The A probe operates at 12 MHz.
Manufacturer illustration: the configuration shown may differ from the delivered configuration.
Several B-mode views
Ultrasound offers B, B+A and B+B views, separate memories for each eye and an approximately 6-second cine loop.
Manufacturer illustration: the configuration shown may differ from the delivered configuration.
Designed for daily practice
Explore the documented features and practical configuration of PIROP A+B+CCT.
Pachymetry and maps
The pachymetry probe operates at 20 MHz. The published range is 220–1100 µm, with nine predefined maps and measurement averaging.
Manufacturer illustration: the configuration shown may differ from the delivered configuration.
Storage and reports
The scanner provides an internal patient database and USB storage. Its internal thermal printer produces A-scan and P-scan reports.
Clearly identified software extensions
PIROP-PC manages examinations on a Windows computer. DICOM 3.0 support for PACS/RIS is an additional option.
PIROP-PC and DICOM are optional; installation is not assumed.
More product details
Display and functions
1. Imaging modes: B, B+A, B+B. 2. A-mode: available on a selected line in Run and Freeze modes. 3. Cineloop: approximately 6 seconds of independent playback for each eye. 4. Image memory: 4 memories (M1 to M4) for each eye.
B-SCAN
1. Technical features • Probe frequency: 12 to 15 MHz. • Scan angle: 55°. • Scan range: 20 to 60 mm. 2. Image quality and adjustments • Gain/dynamic range: up to 110 dB / 90 dB. • TGC: gain adjustment by zone in the selected eye. • Grey levels: 256. • Dynamic range correction. • Digital gain correction in Freeze mode. 3. Resolution • Clinical axial resolution: 0.12 mm. • Clinical lateral resolution: 0.3 mm.
B-scan probe
Frequency: 12/15 MHz. Application: imaging inside the eye, including the retina and optic nerve.
Other B-SCAN features
1. Display modes • Display modes: B, B+A, B+B. • A-mode on a selected CV line in Run and Freeze modes. • Zoom (x2) in Run and Freeze modes. • Independent right- and left-eye cineloop, approximately 6 seconds. 2. Memory and storage • Image cache: M1..M4, independent for right and left eyes. 3. Measurements and annotations • Distance measurements with ultrasound velocity correction. • Area and angle measurements. • User-entered cursors and comments. 4. Output • Composite video output for a video printer.
A-SCAN
Fast, comprehensive biometry: – Axial length (AXL). – Anterior chamber depth (AC). – Lens thickness (LENS). – Vitreous length (VITR). Measurement for different eye types: normal, cataract, dense cataract, aphakia, silicone oil-filled vitreous and pseudophakia (PMMA, ACRYLATE, SILICONE).
A-scan probe
Frequency: 12 MHz. Application: biometry and intraocular lens power calculation.
Six A-SCAN IOL formulas
SRK II, SRK T, Holladay, Hoffer-Q, Binkhorst II, Haggis. Post-refractive formulas: Double-K SRKT, Latkany /Flat-K SRKT/, Latkany /avg-K SRKT/, Masket.
A-SCAN features
1. Methods and functions • Comparison of IOL power calculations for different lenses and calculation methods. • Contact and immersion methods (immersion tube included). • Probe with a central light beam for correct eye positioning. 2. Image quality and adjustments • Automatic TGC adjustment. • GAIN adjustment up to 110 dB. 3. Measurements and analysis • Memory for 20 scans with measurements for later analysis. • Mean and standard deviation calculations. • Automatic measurement dispersion control, with manual correction. 4. Customisation and maintenance • Configurable for 10 users, with 10 profiles per user. • Adjustment and testing using the included calibrator. 5. Technical features • Probe frequency: 12 MHz. • Scan range: 45 mm / 2500 points per line. • Clinical resolution: 0.1 mm. • Electronic resolution: ±0.01 mm.
CCT pachymeter
1. Fast corneal thickness measurements • High measurement frequency: 400 MHz. • 512 automatic measurement cycles. • Thickness measurements for different corneal types. • Central corneal thickness (CCT) measurement. • Thickness measurement at freely selected points. • Automatic and manual measurements. • Mean measurement calculation. • Standard deviation calculation for measured thickness. • Inaccurate measurements can be rejected. 2. Precision and repeatability • Algorithms to improve precision. • High sampling rate.
Pachymetry probe
1. Probe operating frequency: 20 MHz. 2. Default ultrasound velocity: 1640 m/s (range 1400 to 2000 m/s). Technical parameters: • Measurement range: 220 μm to 1100 μm. • Measurement accuracy: ≤2 μm. • Resolution: 1 μm.
Intraocular pressure (IOP) calculations
• Automatic and/or manual calculation of corrected IOP. • 10 IOP correction formulas available: Kohlhas/Shah, Argus et al., Whitarce et al., Doughty, Ehlers, Dresden, Stodmeister, custom user-defined calculation formula.
Predefined corneal thickness maps
• Nine predefined thickness profile maps, with point counts: 1, 5, 9, 13, 21, 25, 1 MULTI, 5 MULTI, 9 MULTI. • Examination of central, paracentral, peripheral, parietal or mixed areas.
Technical information
Technical specifications & documentation
Product information, specifications and available documentation in one place.

Product specifications overview
Key documented information for this exact model.
- Brand
- Echoson
- Model
- PIROP A+B+CCT
- Technology
- Ophthalmic ultrasound
- Clinical use
- Imaging and OCT · Diagnostics and biometry
- Modules
- A-Scan + B-Scan + CCT
Technical specifications
- Minimum pachymetry
- 220 µm
- Maximum pachymetry
- 1100 µm
- A-scan probe
- 12 MHz
- B-scan probe
- 12–15 MHz
- CCT probe
- 20 MHzProbe frequency; internal algorithm frequency excluded.
- B-scan axial resolution
- 0.12 mmAxial clinical resolution in B mode.
- Connectivity
- USB · PAL composite video
- Software
- PIROP-PC optional; DICOM 3 optionalOptions are not assumed included.
- Power supply
- 100–230 V AC ; 50–60 Hz / 12 V DC
- Dimensions
- 290 × 205 × 85 mmWith printer.
- Weight
- 1.5 kgWith printer.
Probe frequency; internal algorithm frequency excluded.
Axial clinical resolution in B mode.
Options are not assumed included.
With printer.
Downloads & resources
Available product sheets and public manufacturer resources.
No public manufacturer document has been verified for this model. Contact ASEM for the available documentation.
Sources and documentation
- https://echoson.pl/en/pirop-en/Verified on 2026-10-05
- https://echoson.pl/en/pirop-en/Verified on 2026-10-17
- https://echoson.pl/en/pirop-en/Verified on 2026-08-30
- https://echoson.pl/en/pirop-en/Verified on 2026-10-18
Frequently asked questions
Your questions about PIROP A+B+CCT
Clear answers based on the available product information.
What is the documented Minimum pachymetry of PIROP A+B+CCT?
220 µm
View sourceWhat is the documented Maximum pachymetry of PIROP A+B+CCT?
1100 µm
View sourceWhich configuration should I confirm for PIROP A+B+CCT?
Probe frequency; internal algorithm frequency excluded.
View sourceDoes the pachymetry probe operate at 400 MHz?
No. The probe is specified at 20 MHz. The manufacturer’s 400 MHz figure concerns internal sampling, not transducer frequency.
View sourceIs DICOM included in every device?
The manufacturer lists PIROP-PC as an optional accessory and DICOM 3.0 as an additional option. Availability must be checked in the ordered configuration.
View sourceASEM support
More than a device, a long-term partnership
Discuss your project with ASEM: equipment selection, installation, training and technical support.
Installation
Discuss the installation requirements and configuration with our technical team.
Learn more

After-sales service
Contact ASEM for technical assistance and the support appropriate to your equipment.
Learn more

Clinical applications
Explore the ASEM clinical catalogue
Browse related areas of the ASEM catalogue. These links do not extend the indications of this device.
Explore all products