Huvitz

HFC-1

Non-mydriatic fundus imaging with panorama acquisition.

The HFC-1 non-mydriatic fundus camera combines high-resolution retinal imaging with fast analysis and automated functions. A colour camera and panoramic imaging without pupil dilation support straightforward operation with a flexible fixation target. Reliable, precise and fast, the HFC-1 supports high-quality diagnostic assessment.

HFC-1 · Equipment view

Key advantages

The documented strengths of HFC-1, at a glance.

Non-mydriatic imaging

Retinal image acquisition with a 45° field.

Panorama view

Panoramic stitching of fundus images.

Small pupil

Acquisition from a pupil diameter of 3.3 mm.

Document the retina

The high-definition colour image provides a clear basis for observation and follow-up.

Adjust image review

Brightness, contrast and gamma controls support review of the acquired image.

Build a panoramic view

The panorama function combines captures to document a wider retinal area.

Capabilities in practice

A closer look at the functions and technology of HFC-1.

HFC-1 · Manufacturer capture
HFC-1 · Manufacturer capture

Manufacturer illustration: the configuration shown may differ from the delivered configuration.

From single capture to panorama

The panorama function stitches fundus images captured at different positions. An adjustable fixation target helps select the photographed areas.

  • Captures at several fixation positions.
  • Image stitching in the panoramic presentation.
View source
HFC-1 · Manufacturer capture
HFC-1 · Manufacturer capture

Manufacturer illustration: the configuration shown may differ from the delivered configuration.

Capture the non-mydriatic fundus

The fundus camera captures a 45° image using the on-screen fixation targets. Small-pupil mode adapts acquisition to pupil diameter.

  • Minimum pupil: 4.0 mm in normal mode, 3.3 mm in small-pupil mode.
  • Internal fixation target and external white-LED target.
View source

Designed for a smoother workflow

Automate tracking and capture

Automatic tracking and shooting support non-mydriatic acquisition. The brochure describes small-pupil handling without a manual mode change.

  • Automatic tracking and automatic shooting.
  • Small-pupil operation without the described manual mode change.
HFC-1 · Manufacturer capture
HFC-1 · Manufacturer capture

Manufacturer illustration: the configuration shown may differ from the delivered configuration.

Designed for daily practice

Explore the documented features and practical configuration of HFC-1.

Review through the integrated system

Colour, blue, red, red-free and cobalt modes provide complementary presentations of the fundus photograph.

  • Image-mode selection after acquisition.
  • EVT visualisation technology described by Huvitz.
HFC-1 · Manufacturer capture
HFC-1 · Manufacturer capture

Manufacturer illustration: the configuration shown may differ from the delivered configuration.

Review images on the device

The built-in PC and touchscreen allow work directly at the acquisition station.

Depending on configuration

  • 12.1-inch touchscreen.
  • Browser review and DICOM interface according to network configuration.
HFC-1 · Manufacturer capture
HFC-1 · Manufacturer capture

Manufacturer illustration: the configuration shown may differ from the delivered configuration.

Technical information

Technical specifications & documentation

Product information, specifications and available documentation in one place.

Product specifications overview

Key documented information for this exact model.

Brand
Huvitz
Model
HFC-1
Technology
Fundus imaging
Clinical use
Imaging and OCT

Manufacturer’s minimum value.

Small-pupil mode; normal mode 4 mm.

Downloads & resources

Available product sheets and public manufacturer resources.

No public manufacturer document has been verified for this model. Contact ASEM for the available documentation.

Sources and documentation

Frequently asked questions

Your questions about HFC-1

Clear answers based on the available product information.

What is the documented Field of view of HFC-1?
What is the documented Central resolution of HFC-1?

60 lignes/mm — Manufacturer’s minimum value.

View source
Which configuration should I confirm for HFC-1?

Manufacturer’s minimum value.

View source
Does HFC-1 produce OCT sections?

HFC-1 is a fundus camera. It provides photographs, viewing modes and panoramas; the brochure does not describe it as a tomographic OCT instrument.

View source
How is the panoramic image produced?

It is stitched from several photographs acquired at different fixation positions. It is distinct from a single 45° photograph.

View source
Is an external computer needed for local acquisition?

HFC-1 includes a built-in PC and a 12.1-inch touchscreen. Network and DICOM review require the corresponding installation to be configured.

View source

ASEM support

More than a device, a long-term partnership

Discuss your project with ASEM: equipment selection, installation, training and technical support.

Installation

Discuss the installation requirements and configuration with our technical team.

Learn more
Service illustration
Service illustration

Training

Ask about the training and familiarisation available for your equipment.

Learn more
Service illustration
Service illustration

After-sales service

Contact ASEM for technical assistance and the support appropriate to your equipment.

Learn more
Service illustration
Service illustration

Expert advice

Tell us about your clinical needs to discuss a suitable equipment selection.

Learn more
Service illustration
Service illustration

Clinical applications

Explore the ASEM clinical catalogue

Browse related areas of the ASEM catalogue. These links do not extend the indications of this device.

Explore all products