HVF-100
Visual field assessment with white-on-white static perimetry.
Blind spot testing, horizontal visual angle assessment and programs for neurological eye conditions support assessment and monitoring of optic nerve disorders, glaucoma, visual impairment and retinal disease.
Key advantages
The documented strengths of HVF-100, at a glance.
Static perimetry
White-on-white visual field examination.
Field up to 90°
Perimetric examination of fields up to 90°.
Goldmann III stimulus
Goldmann III stimulus size for visual field tests.
Capabilities in practice
A closer look at the functions and technology of HVF-100.
Explore the static visual field
HVF-100 presents white Goldmann III stimuli on a white background. The specification gives a maximum 90° field and a 1–10,000 asb intensity range.
- White Goldmann III stimulus on a white background.
- Background: 31.5 asb; maximum field: 90°.
Define stimulus parameters
The static protocol uses the documented intensity, duration and position parameters.
- Intensity from 1 to 10,000 asb; display from 0 to 40 dB.
- 200 ms/adaptive duration; 456 available positions.
Designed for a smoother workflow
Monitor fixation during the test
The brochure combines Heijl/Krakau blind-spot monitoring, an eye video monitor and gaze tracking. These indicators support review of result reliability.
- Heijl/Krakau blind-spot monitoring.
- Eye video, head tracking and gaze tracking.
Adjust positioning from the station
The chinrest and forehead rest move together during positioning adjustment.
- Controls through touchscreen, keyboard/mouse or buttons.
- Automatic eye-position calibration.
Designed for daily practice
Explore the documented features and practical configuration of HVF-100.
Review a structured perimetry report
Report examples present the single field, deviations and indices including MD, PSD, GHT and VFI. The manufacturer illustrates monocular and binocular reports.
- Single-field and deviation presentation.
- Illustrated indices: MD, PSD, GHT and VFI.
More product details
Precise measurement
Measurement conforming to Goldmann standards assesses the visual field with different stimulus sizes and intensities against white and black backgrounds, measuring visual sensitivity and extent.
Test programs
Blind spot testing, horizontal visual angle assessment and neurological eye test programs are included to assess and monitor conditions such as optic nerve disorders, glaucoma, visual impairment and retinal disease.
Convenient measurement
Automatic OD/OS recognition alerts the operator to help prevent examination errors. The system automatically measures pupil diameter during testing to correct visual errors and provides spoken guidance through the test for convenient measurement.
Technical specifications
Displayed dB range: 0-40db. Stimulus intensity range: 1asb-10000asb. Stimulus size: Goldmann III. Stimulus colour: white. Stimulus duration: 200ms/adaptive. Maximum measurement field: 90°. Test distance: 30cm. Test mode: static. Number of stimulus locations: 456 points. Stimulus plane: aspherical surface. White background luminance: 31.5asb (10cd/m²). Custom test program. Automatic eye recognition. Blind spot area test. Stimulus source: LED.
Technical information
Technical specifications & documentation
Product information, specifications and available documentation in one place.

Product specifications overview
Key documented information for this exact model.
Technical specifications
- Stimulus sizes
- Goldmann III
- Maximum stimulus intensity
- 10000 asb
- Maximum test field
- 90 °
- Connectivity
- Ethernet · Wi-Fi
- Power supply
- 100–240 V AC ; 50–60 Hz
- Dimensions
- 480 × 430 × 528 mm
- Weight
- 14 kg
Downloads & resources
Available product sheets and public manufacturer resources.
No public manufacturer document has been verified for this model. Contact ASEM for the available documentation.
Sources and documentation
Frequently asked questions
Your questions about HVF-100
Clear answers based on the available product information.
What is the documented Stimulus sizes of HVF-100?
Goldmann III
View sourceWhat is the documented Maximum stimulus intensity of HVF-100?
10000 asb
View sourceDoes this specification describe kinetic perimetry?
The HVF-100 specification lists a static test mode. It does not establish a kinetic protocol for this instrument.
View sourceWhich indicators help review fixation?
The manufacturer describes Heijl/Krakau monitoring, eye video, head and gaze tracking, and the tracking curve. These complement the report indicators.
View sourceWhich stimulus is documented?
The specification gives a white Goldmann III stimulus lasting 200 ms or adaptively, on a 31.5 asb white background. The test mode is static.
View sourceASEM support
More than a device, a long-term partnership
Discuss your project with ASEM: equipment selection, installation, training and technical support.
Installation
Discuss the installation requirements and configuration with our technical team.
Learn more

After-sales service
Contact ASEM for technical assistance and the support appropriate to your equipment.
Learn more

Related products
Explore equipment with related technologies and clinical uses.
Clinical applications
Explore the ASEM clinical catalogue
Browse related areas of the ASEM catalogue. These links do not extend the indications of this device.
Explore all products