BVI Medical

R-Evolution CR

Phacoemulsification and anterior and posterior vitrectomy.

The R-Evolution CR is a versatile platform for ophthalmic surgery. It combines advanced technology with an intuitive interface to support surgical performance and the user experience.

R-Evolution CR · Equipment view

Key advantages

The documented strengths of R-Evolution CR, at a glance.

Combined surgery

Phaco and anterior and posterior vitrectomy.

Dual aspiration system

Choice of peristaltic and Venturi pumps.

Ultrasound phaco

Continuous, pulsed or burst emission at about 40 kHz.

Set fluidics

The interface combines pump and irrigation settings for the combined procedure.

R-Evolution CR · Manufacturer interface
R-Evolution CR · Manufacturer interface

Manufacturer illustration: the configuration shown may differ from the delivered configuration.

Control vitrectomy

The operating view documents settings dedicated to vitreoretinal steps.

R-Evolution CR · Manufacturer interface
R-Evolution CR · Manufacturer interface

Manufacturer illustration: the configuration shown may differ from the delivered configuration.

Capabilities in practice

A closer look at the functions and technology of R-Evolution CR.

Designed for a smoother workflow

Two aspiration modes

R-Evolution CR lets the operator program vacuum and flow for the selected mode.

  • Peristaltic and Venturi pumps.
  • Vacuum: 5–700 mmHg.
  • Peristaltic flow: 1–90 ml/min.

Active or gravity-fed irrigation

Active irrigation is microprocessor controlled. The sheet also describes gravity-fed delivery with foot-pedal control.

Designed for daily practice

Explore the documented features and practical configuration of R-Evolution CR.

Selectable phaco modes

The piezoelectric handpiece operates at approximately 40 kHz, with fixed or linear foot-pedal power control.

  • Continuous, pulsed or burst emission.
  • Autolimit and HD Pulse occlusion modes.

Controlled anterior vitrectomy

The pneumatic cutter provides 60–10,000 cuts/min. With Twedge technology, the stated range is 120–20,000 cuts/min.

Twedge rates require the corresponding cutter; they do not describe every accessory.

  • Fixed or linear foot-pedal control.

Adjustable bipolar diathermy

The 2 MHz bipolar generator has a nominal output of 9 W at a 200-ohm load, adjustable from 5% to 100%.

Foot-controlled settings

The pedal controls the irrigation, aspiration, phaco and vitrectomy functions documented in the sheet. Default settings are programmable by function.

A retinal configuration

The CR version combines posterior vitrectomy with 3 independent LED sources. Auxiliary functions include fluid/air exchange and silicone-oil handling.

  • The standard R-Evolution configuration must not be treated as the CR version.
View source

Technical information

Technical specifications & documentation

Product information, specifications and available documentation in one place.

Product specifications overview

Key documented information for this exact model.

Brand
BVI Medical
Model
R-Evolution CR
Technology
Phacoemulsification
Clinical use
Cataract and retinal surgery

Approximate frequency; it does not establish clinical superiority.

Peristaltic mode only.

Standard anterior probe; optional TWEDGE maximum excluded.

Endo-illumination; no zero value is inferred for undocumented models.

Complete console on cart.

Complete tower; configuration not comparable to the weight of a console alone.

Downloads & resources

Available product sheets and public manufacturer resources.

No public manufacturer document has been verified for this model. Contact ASEM for the available documentation.

Sources and documentation

Frequently asked questions

Your questions about R-Evolution CR

Clear answers based on the available product information.

What is the documented Phaco frequency of R-Evolution CR?

40 kHz — Approximate frequency; it does not establish clinical superiority.

View source
What is the documented Maximum vacuum of R-Evolution CR?

700 mmHg

View source
Which configuration should I confirm for R-Evolution CR?

Approximate frequency; it does not establish clinical superiority.

View source
Which aspiration system does R-Evolution CR use?

Peristaltic and Venturi pumps.

View source
How should the vitrectomy rates be read?

This variant’s sheet distinguishes 60–10,000 cuts/min from 120–20,000 with Twedge. The ordered handpiece and configuration must match.

View source
Is gravity irrigation also documented?

Yes. The sheet describes microprocessor-controlled active irrigation and gravity delivery. The exact station equipment must be confirmed when configuring it.

View source

ASEM support

More than a device, a long-term partnership

Discuss your project with ASEM: equipment selection, installation, training and technical support.

Installation

Discuss the installation requirements and configuration with our technical team.

Learn more
Service illustration
Service illustration

Training

Ask about the training and familiarisation available for your equipment.

Learn more
Service illustration
Service illustration

After-sales service

Contact ASEM for technical assistance and the support appropriate to your equipment.

Learn more
Service illustration
Service illustration

Expert advice

Tell us about your clinical needs to discuss a suitable equipment selection.

Learn more
Service illustration
Service illustration

Clinical applications

Explore the ASEM clinical catalogue

Browse related areas of the ASEM catalogue. These links do not extend the indications of this device.

Explore all products