Eyestar 900
Optical biometry and keratometry in a system using EyeSuite.
Swept-source OCT biometry from the cornea to the retina.
Key advantages
The documented strengths of Eyestar 900, at a glance.
Swept-source OCT biometry
Swept-source OCT biometry from the cornea to the retina.
Corneal mapping
Topography and pachymetry tools for corneal assessment.
Automated data acquisition
Automated acquisition designed to measure both eyes.
Capabilities in practice
A closer look at the functions and technology of Eyestar 900.
Manufacturer illustration: the configuration shown may differ from the delivered configuration.
Comprehensive planning
Biometry, keratometry and corneal topography combined to prepare each case.
View source
Manufacturer illustration: the configuration shown may differ from the delivered configuration.
Cornea and anterior segment
Anterior and posterior corneal topography, pachymetry and detailed OCT sections.
View source
Manufacturer illustration: the configuration shown may differ from the delivered configuration.
EyeSuite integration
Data flows into the EyeSuite ecosystem for a coherent clinical workflow.
View source
Manufacturer illustration: the configuration shown may differ from the delivered configuration.
Manufacturer illustration: the configuration shown may differ from the delivered configuration.
From cornea to retina
Swept-source OCT biometry combines axial dimensions, keratometry and ocular sections. Corneal maps complement the measurements; this does not make the system a diagnostic retinal OCT.
View source
Manufacturer illustration: the configuration shown may differ from the delivered configuration.
Support IOL planning
Cataract Suite combines anterior and posterior topography, pachymetry and lens-tilt analysis. EyeSuite IOL brings calculation data and toric planning together.
View source
Manufacturer illustration: the configuration shown may differ from the delivered configuration.
Explore the anterior segment
Anterior Chamber Suite documents topography up to 12 mm and OCT imaging up to 18 mm. These ranges do not describe every Eyestar configuration.
Functions and ranges depend on the selected software suite.
View sourceDesigned for a smoother workflow
Automated acquisition of both eyes
The manufacturer reports a typical 40-second acquisition for both eyes. This concerns measurement, not the complete appointment or a guarantee for every patient.
Review maps and change over time
Anterior Chamber Suite difference and progression views compare maps and indices. Belin ABCD staging remains an aid to clinical assessment.
Subject to the configured suite and licences.
Manufacturer illustration: the configuration shown may differ from the delivered configuration.
Designed for daily practice
Explore the documented features and practical configuration of Eyestar 900.
Reuse measurements in EyeSuite
EyeSuite links acquisition, IOL calculation and review stations. Patient-record integration must be defined against the installation’s interfaces and licences.
More product details
BIOMETRY AND IOL CALCULATION
Features Corneal maps: diameter up to 12 mm. Spherical elevation with 3 mm exclusion. Difference maps. Progression view. Corneal ectasia view. Belin ABCD classification. K-Max pachymetric spatial profiles. Scan diameter up to 18 mm (0.7 inches).
Biometry and premium IOL calculation
Premium refractive IOL calculation • Toric and multifocal implants in cataract surgery. • Precise toric lens planning through thorough, reliable axis analysis, reducing errors and the need for adjustments. Advanced analysis of ocular structures: • Crystalline lens tilt and decentration. • Dynamic pupillometry over an extended range of 2 to 13 mm. • Comprehensive, detailed analysis of ocular structures. • Optimisation of toric lens positioning.
Zernike analysis and vision simulation
Identifies the symmetry and regularity of anterior and posterior astigmatism.
Mandala scan
No rescanning Thanks to the dense mandala scan pattern. Radial scans or stacks of linear scans. Individual B-scans. OCT scan diameter of 18 mm.
Anterior and posterior topography
Advanced detection of corneal disease Detailed corneal topography for keratoconus. Integrated Belin ABCD classification. Detailed pachymetry maps and analyses. Analysis of curvature and elevation. Ectasia monitoring. Topography of peripheral areas up to 12 mm.
Technical features
1. Axial length (AL) • Measurement range: 14 - 38 mm • Resolution: 0.01 mm 2. Keratometry (K) • K measurement range: 32.1 - 67.5 dpt • K display resolution: 0.01 dpt • Axis measurement range: 0 - 180° • Axis display resolution: 1° 3. White-to-white distance • Measurement range: 7 - 16 mm • Resolution: 0.01 mm 4. Pupillometry (PD) • Measurement range: 2 - 13 mm • Resolution: 0.01 mm 5. Topography • Covered area (diameter): standard 7.5 mm / extended 12 mm 6. Simulated anterior keratometry (SimEK - 12 mm diameter) • SimEK measurement range: 32.1 - 67.5 dpt • SimEK resolution: 0.01 dpt • Axis measurement range: 0 - 180° • Axis display resolution: 1° • Corneal shape factor resolution: 0.01 7. Simulated posterior keratometry (SimEPK - 12 mm diameter) • SimEPK measurement range: 3.9 - 9.5 dpt • SimEPK resolution: 0.01 dpt • Axis measurement range: 0 - 180°
Technical information
Technical specifications & documentation
Product information, specifications and available documentation in one place.

Product specifications overview
Key documented information for this exact model.
- Brand
- Haag-Streit
- Model
- Eyestar 900
- Technology
- Optical biometer
- Clinical use
- Diagnostics and biometry · Cataract and retinal surgery
- Technologies
- Optical biometry, keratometry, topography, pachymetry and swept-source OCT
Technical specifications
- Software
- EyeSuite
Downloads & resources
Available product sheets and public manufacturer resources.
No public manufacturer document has been verified for this model. Contact ASEM for the available documentation.
Sources and documentation
- https://haag-streit.com/en/products/categories/specialty-diagnostics/biometry/eyestar-900Verified on 2026-10-05
- https://haag-streit.com/en/products/categories/specialty-diagnostics/biometry/eyestar-900Verified on 2026-10-17
- https://haag-streit.com/en/products/categories/specialty-diagnostics/biometry/eyestar-900Verified on 2026-08-30
- https://haag-streit.com/en/products/categories/specialty-diagnostics/biometry/eyestar-900Verified on 2026-10-18
- https://jp.haag-streit.com/2%20Products/Speciality%20diagnostics/Biometry/Eyestar%20900/Brochures/English/HS_eyestar_900_br_7220720_sweptsource_oct_for_cataract_and_refractive_surgery.pdfVerified on 2026-10-18
- https://jp.haag-streit.com/2%20Products/Speciality%20diagnostics/Biometry/Eyestar%20900/Brochures/English/HS_eyestar_900_br_7220720_sweptsource_oct_for_cataract_and_refractive_surgery.pdfVerified on 2026-10-18
- https://jp.haag-streit.com/2%20Products/Speciality%20diagnostics/Biometry/Eyestar%20900/Brochures/English/HS_eyestar_900_br_7220720_sweptsource_oct_for_cataract_and_refractive_surgery.pdfVerified on 2026-10-18
- https://jp.haag-streit.com/2%20Products/Speciality%20diagnostics/Biometry/Eyestar%20900/Brochures/English/HS_eyestar_900_br_7220720_sweptsource_oct_for_cataract_and_refractive_surgery.pdfVerified on 2026-10-18
- https://jp.haag-streit.com/2%20Products/Speciality%20diagnostics/Biometry/Eyestar%20900/Brochures/English/HS_eyestar_900_br_7220720_sweptsource_oct_for_cataract_and_refractive_surgery.pdfVerified on 2026-10-18
- https://haag-streit.com/en/products/categories/specialty-diagnostics/biometry/eyestar-900Verified on 2026-10-18
- https://jp.haag-streit.com/2%20Products/Speciality%20diagnostics/Biometry/Eyestar%20900/Brochures/English/HS_eyestar_900_br_7220720_sweptsource_oct_for_cataract_and_refractive_surgery.pdfVerified on 2026-10-18
- https://jp.haag-streit.com/2%20Products/Speciality%20diagnostics/Biometry/Eyestar%20900/Brochures/English/HS_eyestar_900_br_7220720_sweptsource_oct_for_cataract_and_refractive_surgery.pdfVerified on 2026-10-18
Frequently asked questions
Your questions about Eyestar 900
Clear answers based on the available product information.
What is the documented Software of Eyestar 900?
EyeSuite
View sourceWhich imaging technology does Eyestar 900 use?
The manufacturer describes swept-source OCT for biometry and anterior-segment analysis.
View sourceAre Eyestar 900 Cataract Suite and Anterior Chamber Suite identical?
No. The manufacturer provides separate feature columns for the two suites.
View sourceIs 12 mm topography available in every Eyestar 900 suite?
No. The table distinguishes topography up to 7.5 mm for Cataract Suite from up to 12 mm for Anterior Chamber Suite.
View sourceIs the 18 mm anterior OCT range common to all Eyestar 900 suites?
No. The table distinguishes 7.5 mm and 18 mm anterior OCT ranges by suite.
View sourceWhich planning software is presented with Eyestar 900?
The product page presents EyeSuite IOL for surgical planning. Configuration and licences must be confirmed.
View sourceDo 40 seconds cover the complete appointment?
No. The manufacturer describes typical acquisition time for both eyes, not the complete consultation.
View sourceCan sections be reviewed from an acquired volume?
Anterior Chamber Suite can create virtual B-scans within the volume acquired by the Mandala scan.
View sourceASEM support
More than a device, a long-term partnership
Discuss your project with ASEM: equipment selection, installation, training and technical support.
Installation
Discuss the installation requirements and configuration with our technical team.
Learn more

After-sales service
Contact ASEM for technical assistance and the support appropriate to your equipment.
Learn more

Related products
Explore equipment with related technologies and clinical uses.
Clinical applications
Explore the ASEM clinical catalogue
Browse related areas of the ASEM catalogue. These links do not extend the indications of this device.
Explore all products