HRK-8100A
Automatic refraction with central and peripheral keratometry.
Sphere from −30 to +25 D; cylinder up to 12 D.
Key advantages
The documented strengths of HRK-8100A, at a glance.
Automatic refraction
Sphere from −30 to +25 D; cylinder up to 12 D.
Peripheral cornea
Central and peripheral keratometry in one examination.
Lens curvature
Contact lens curvature measurement.
Visualise the wavefront
The refractive map represents variations used in optical analysis.
Manufacturer illustration: the configuration shown may differ from the delivered configuration.
Detail aberrations
Zernike analysis organises aberrations in a dedicated view.
Compare measurements
The report groups refraction and keratometry values for structured review.
Capabilities in practice
A closer look at the functions and technology of HRK-8100A.
Manufacturer illustration: the configuration shown may differ from the delivered configuration.
Read aberrations on a Zernike map
The micro-lens array measures the wavefront. Alongside sphere, cylinder and axis, the Zernike map displays coma, trefoil and spherical aberration, among others.
- Sphere, cylinder and axis results.
- Zernike representation of aberrations.
Manufacturer illustration: the configuration shown may differ from the delivered configuration.
Add observation to the measurements
IOL and retro-illumination modes complement measurements in the described implant and lens-opacity situations. Color View provides a colour view of the eye and contact-lens fitting.
- Colour camera and white LED for Color View.
- Separate IOL and retro-illumination modes.
Manufacturer illustration: the configuration shown may differ from the delivered configuration.
Detail higher-order aberrations
The Zernike map complements refraction values with a representation of wavefront components.
- Coma, trefoil and spherical aberration.
- Secondary astigmatism and tetrafoil.
Manufacturer illustration: the configuration shown may differ from the delivered configuration.
Position the diameter markers
Eye capture allows the iris and pupil to be measured in the dedicated mode.
- Diameter range from 2 to 14 mm.
- Colour view for contact-lens observation.
Designed for a smoother workflow
Measure central and peripheral cornea
Peripheral keratometry records curvature and eccentricity around the centre. The fitting guide brings together blue-light observations and keratometry values.
- Curvature review beyond the corneal centre.
- Curvature and eccentricity parameters.
Designed for daily practice
Explore the documented features and practical configuration of HRK-8100A.
Prepare centration before measurement
Automatic tracking and height controls support patient positioning.
- Up and down controls.
- Acquisition guidance in the interface.
More product details
Key functions
Wavefront technology: a Huvitz microlens array analyses multiple focal points in a light wavefront for precise detection of refractive errors. Aberration map: alongside conventional sphere, cylinder and axis data, the HRK-8100A provides a graphical higher-order aberration map to support detailed ocular assessment and clinical decisions. IOL and RET-ILLUM modes: designed for eyes with intraocular lenses or cataracts, these modes allow observation of lens opacity or corneal damage associated with contact lens wear. Colour viewing mode: a colour CCD camera and white LED illumination assess contact lens fit, a function previously associated with slit lamps. Intuitive interface: consistent icons and muted colours reduce visual fatigue and facilitate navigation.
Medical features
Wavefront analysis: A microlens array provides detailed measurement of refractive errors and aberrations. Zernike aberration map: Displays higher-order aberrations for detailed assessment of the eye's optical quality. Specialised IOL and cataract modes: Dedicated assessment for eyes with intraocular lenses or cataracts. Contact lens assessment: Colour viewing assists precise contact lens fitting directly on the instrument. LED technology and CCD camera: Enhanced images and measurements support clinical precision.
The HRK-8100A in medical practice
Precise, fast assessment: Wavefront technology and Zernike aberration mapping provide detailed refractive error analysis for accurate prescriptions. Comprehensive eye assessment: Dedicated intraocular lens and cataract modes accommodate patients with complex conditions and provide reliable measurements. Personalised care: Colour contact lens viewing assists fitting, reducing discomfort and improving patient satisfaction. Time savings for professionals: An intuitive interface and advanced functions support efficient consultations. Patient comfort: Non-invasive measurement and advanced technology make examinations more comfortable while providing high-quality results.
Zernike
Wavefront analysis: A microlens array provides detailed measurement of refractive errors and aberrations. Zernike aberration map: Displays higher-order aberrations for detailed assessment of the eye's optical quality. Specialised IOL and cataract modes: Dedicated assessment for eyes with intraocular lenses or cataracts.
Technical information
Technical specifications & documentation
Product information, specifications and available documentation in one place.

Product specifications overview
Key documented information for this exact model.
- Brand
- Huvitz
- Model
- HRK-8100A
- Technology
- Refractor / auto-refractor
- Clinical use
- Diagnostics and biometry
Technical specifications
- Minimum sphere
- -30 DVertex distance 12 mm.
- Maximum sphere
- 25 D
- Maximum cylinder
- 12 D
- Minimum pupil diameter
- 2 mm
- Adjustment ranges
- Vertical 30 mm; lateral 10 mm; longitudinal 10 mm; chin rest 60 mm
- Power supply
- 100–240 V AC ; 50–60 Hz
- Dimensions
- 524 × 262 × 439 mm
- Weight
- 20.5 kg
Vertex distance 12 mm.
Downloads & resources
Available product sheets and public manufacturer resources.
No public manufacturer document has been verified for this model. Contact ASEM for the available documentation.
Sources and documentation
- https://huvitz.com/wp-content/uploads/2025/02/20241203_HRK-8100A_eng_catalog_v2.pdfVerified on 2026-10-05
- https://huvitz.com/en/product/hrk-8100a/Verified on 2026-08-30
- https://huvitz.com/en/product/hrk-8100a/Verified on 2026-10-18
- https://huvitz.com/wp-content/uploads/2025/02/20241203_HRK-8100A_eng_catalog_v2.pdfVerified on 2026-10-18
Frequently asked questions
Your questions about HRK-8100A
Clear answers based on the available product information.
What is the documented Minimum sphere of HRK-8100A?
-30 D — Vertex distance 12 mm.
View sourceWhat is the documented Maximum sphere of HRK-8100A?
25 D
View sourceWhich configuration should I confirm for HRK-8100A?
Vertex distance 12 mm.
View sourceWhich iris and pupil measurements are described?
The brochure describes image-based diameter measurement from 2 to 14 mm. This is separate from refraction, keratometry and colour-observation modes.
View sourceWhat does the Zernike map add to SPH/CYL/AX results?
It represents coma, trefoil, spherical aberration, secondary astigmatism and tetrafoil, among others. These components complement the standard refractive values.
View sourceWhich viewing modes are described?
The manufacturer page distinguishes Color View, IOL and retro-illumination. The colour camera and white LED support eye observation; the contact-lens fitting guide uses blue illumination.
View sourceASEM support
More than a device, a long-term partnership
Discuss your project with ASEM: equipment selection, installation, training and technical support.
Installation
Discuss the installation requirements and configuration with our technical team.
Learn more

After-sales service
Contact ASEM for technical assistance and the support appropriate to your equipment.
Learn more

Related products
Explore equipment with related technologies and clinical uses.
Clinical applications
Explore the ASEM clinical catalogue
Browse related areas of the ASEM catalogue. These links do not extend the indications of this device.
Explore all products



